  1. Why does this presumably 15A GFCI say its a 20A receptacle?

    Aug 14, 2024 · A UL requirement is that all 15A faced receptacles (i.e. NEMA 5-15 sockets) must have 20A passthru. The companion rule to this is NEC 210.21 (B) (3) which allows 15A …

  2. Why is it safe to use 15 A receptacles on a 20 A circuit?

    A 15A outlet is rated for 15A, with a 20A pass through. That is to say that the 20A circuit is in continuance throughout the circuit, however the receptacle itself (the contacts) are rated for …

  3. Is it OK to replace a 15A outlet with 20A outlet as long as it's ...

    Jun 25, 2020 · The garage has one 15A outlet, a few lights, and two garage doors. I want to plug in a treadmill into the garage. The treadmill has a NEMA 5-20P plug on it and has a label that …

  4. 15 amp 2-pole breaker, what wire size is needed

    Aug 7, 2021 · Ideally check the unit specs, or call the "AC guys" yourself to verify - 14/2 is probably perfectly fine - you can oversize the wire and the size of the wire if it makes you or …

  5. electrical - Why does US Code not allow a 15A single receptacle …

    Dec 6, 2020 · What am I missing about why a 15A single receptacle cannot be the only connection to a 20A circuit? (This answer quotes more of Code 210.21, and goes into more …

  6. Would there be a problem installing 20A switches on a 15A circuit?

    There is no problem with using a 20A switch on a 15A circuit, as the breaker will trip and protect the switch from over-current. Using a 15A switch on a 20A circuit is potentially dangerous …

  7. appliances - Home Improvement Stack Exchange

    I've searched the answer which seems to be 1800W (120V x 15a) but it's not clear to me whether the rating is for each of the two outlets or the pair together. So I would like to know: what is the …

  8. What is the purpose of a double pole breaker for separate 15A …

    4 My new house is done being built and I am going to come in and install my new gas range and dishwasher, both 120V 15A appliances. I got thoroughly confused looking at the breaker box …

  9. How to hook up a 240 volt, 15 amp appliance (with neutral) in the …

    Apr 20, 2025 · A quick look on The River shows 50ft 12/3 and 10/3 very similar in price in April 2025 ($90 plus/minus $5). Having to use uncommon 240V 15A items may boost the price …

  10. electrical - GFCI outlet shape for 20 amp vs 15 amp circuit - what …

    Jun 17, 2017 · Underwriter's Laboratories requires that all 15A (on their face) receptacles have, internally, circuit paths which are rated for 20A. That dances together with the Electrical Code, …